TECHNICAL DATA |
|
|
|
|
|
|
|
|
RECEIVING UNIT MODEL |
M880 S AC |
M880 S DC |
M880 S DC |
|
|
Harting connector (PCB415) |
AMP Automotive (PCB410) |
Supply voltage |
24Vac (50-60HZ) 11÷30 Vdc |
11÷30 Vdc |
11÷30 Vdc |
Safety control |
1 safety-enable relay, 2 Stop relays |
1 safety-enable relay, 2 Stop relays |
1 safety-enable relay, 2 Stop relays |
Max. no. of ON/OFF controls |
14 relays |
Up to 14 MOSFET |
8 MOSFET |
2 STOP relays |
ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) |
ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) |
ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) |
or |
or |
or |
ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) |
ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) |
ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) |
(with ARES2 C) |
(with ARES2 C) |
(with ARES2 C) |
(with WAVE2 C) |
(with WAVE2 C) |
(with WAVE2 C) |
Max. no. of analog controls |
N.D. |
4 |
N.D. |
Service commands |
Start, Horn |
Start, Horn |
Start, Horn, |
Serial ports |
N.D. |
CAN, RS232, RS485 |
CAN, RS232, RS485 |
Analog commands |
N.D. |
0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) with Vccmax=28Vdc, |
N.D. |
0 ÷ ±10Vdc |
PWM 0÷1,4A (F=40÷150Hz; F=200÷600Hz; F=600÷1000Hz), 25%-50%-75% Vcc |
Operating temperature |
-25°C ÷ +70°C |
-25°C ÷ +70°C |
-25°C ÷ +70°C |
Storage temperature |
-40°C ÷ +85°C |
-40°C ÷ +85°C |
-40°C ÷ +85°C |
Size (L x P x A) |
127 x 70 x 147 mm |
127 x 70 x 147 mm |
127 x 70 x 147 mm |
Weight |
630 g |
630 g |
630 g |
Serial cable between TX and RX |
YES * |
YES |
YES * |
Integrated blinklight |
YES |
NO |
NO |
External antenna |
YES ** |
YES ** |
NO |
Protection class |
IP 66 |
IP 66 |
IP 66 |