| TECHNICAL DATA | |||
| RECEIVING UNIT MODEL | M880 S AC | M880 S DC | M880 S DC |
| Harting connector (PCB415) | AMP Automotive (PCB410) | ||
| Supply voltage | 24Vac (50-60HZ) 11÷30 Vdc | 11÷30 Vdc | 11÷30 Vdc |
| Safety control | 1 safety-enable relay, 2 Stop relays | 1 safety-enable relay, 2 Stop relays | 1 safety-enable relay, 2 Stop relays |
| Max. no. of ON/OFF controls | 14 relays | Up to 14 MOSFET | 8 MOSFET |
| 2 STOP relays | ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) | ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) | ISO 13849-1:2006 6.2.7 architecture, (PLe Cat 4) |
| or | or | or | |
| ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) | ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) | ISO 13849-1:2006 6.2.6 architecture, (PLc Cat 1) | |
| (with ARES2 C) | (with ARES2 C) | (with ARES2 C) | |
| (with WAVE2 C) | (with WAVE2 C) | (with WAVE2 C) | |
| Max. no. of analog controls | N.D. | 4 | N.D. |
| Service commands | Start, Horn | Start, Horn | Start, Horn, |
| Serial ports | N.D. | CAN, RS232, RS485 | CAN, RS232, RS485 |
| Analog commands | N.D. | 0÷20mA, 4÷20mA, 0Vdc - (Vdc-3) with Vccmax=28Vdc, | N.D. |
| 0 ÷ ±10Vdc | |||
| PWM 0÷1,4A (F=40÷150Hz; F=200÷600Hz; F=600÷1000Hz), 25%-50%-75% Vcc | |||
| Operating temperature | -25°C ÷ +70°C | -25°C ÷ +70°C | -25°C ÷ +70°C |
| Storage temperature | -40°C ÷ +85°C | -40°C ÷ +85°C | -40°C ÷ +85°C |
| Size (L x P x A) | 127 x 70 x 147 mm | 127 x 70 x 147 mm | 127 x 70 x 147 mm |
| Weight | 630 g | 630 g | 630 g |
| Serial cable between TX and RX | YES * | YES | YES * |
| Integrated blinklight | YES | NO | NO |
| External antenna | YES ** | YES ** | NO |
| Protection class | IP 66 | IP 66 | IP 66 |